Description: 1st transfer High-voltage output trouble
Causes: Open circuit of the 1st transfer out put.
Remedy: 1) Check & Remedy Use SIM8-6 to check the out put of [1TC-K/C/M/Y].If the leakage noise or the flickering on the screen of the panel is detected; (1) Abnormality of 1ST transfer unit. --> Remove and insert the 1ST transfer unit. --> Replace the 1ST transfer unit. (2) Imperfect insertion the 1ST transfer unit. --> Remove and insert the 1ST transfer unit. (3) Abnormality of the 1TC-K/C/M/Y harness. --> Check 1TC-K/C/M/Y wiring.Replace. (4) Abnormality of the high voltage TC PWB spring contact. --> Check the high voltage TC PWB spring contact. (5) High TC PWB trouble. --> Replace the high TC PWB. (6) PCU PWB trouble. --> Replace the PCU PWB. 2) Check & Remedy Check the operation of the 1ST transfer separation clutch1/2(1TURC_1,1TURC_2). If the clutch or gera do not move smoothly or have noise, (1) Abnormality of 1ST transfer separation clutch. --> Check connection of harness and check the clutch. --> Replace the clutch. (2) Abnormality of 1ST transfer unit. --> Check the 1ST transfer unit. --> Replace the 1ST transfer unit. 3) Check & Remedy Check the operation of OPC Drum. If it is not normal movement, (1) Abnormality of Drum drive motor (DVM_K.DVM_CL). --> Check Drum drive motor (DVM_K,DVM_CL). (2) Abnormality of OPC Drum (K/C/M/Y). --> Check OPC Drum (K/C/M/Y). --> Replace OPC Drum (K/C/M/Y).