Mã lỗi E7-28 — Sharp MX4500FN

Code: E7-28

Description: LSU control ASIC connection abnormality
Access error between the CPU of the PCU PWB and the LSU control ASIC
Causes: <When this trouble occurs in the initial process on turn on the power> Communication connector trouble between the PCU PWB and the LSUcnt PWB (interface PWB). Harness trouble. <When this trouble occurs on starting printing/during printing, and SIM61-1 is used to check the LSU unit operation for each of B/W and COLOR and the judgment is NG.> Connected the connector between the PCU PWB and the LSUcnt PWB (interface PWB) / Harness trouble PCU PWB or LSUcnt PWB (interface PWB) trouble
Remedy: Case 1 Cause <When this trouble occurs in the initial process on turn on the power> Communication connector trouble between the PCU PWB and the LSUcnt PWB (interface PWB). Harness trouble. Check and remedy Check the connector connection between the PCU PWB and the LSUcnt PWB (interface PWB). Check the harness. If the trouble cannot be removed, replace the LSUcnt PWB or the PCU PWB. Case 2 Cause <When this trouble occurs on starting printing/during printing, and SIM61-1 is used to check the LSU unit operation for each of B/W and COLOR and the judgment is NG.> Connected the connector between the PCU PWB and the LSUcnt PWB (interface PWB) / Harness trouble Check and remedy Check the harness between the PCU PWB and the LSUcnt PWB (interface PWB). If the trouble cannot be removed, replace the LSUcnt PWB or the PCU PWB. Case 3 Cause PCU PWB or LSUcnt PWB (interface PWB) trouble Check and remedy Replace the PCU PWB or the LSUcnt PWB (interface PWB).

← Xem tất cả mã lỗi Sharp MX4500FN

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie