Code: F2-82
Description: Half tone process control 1st patch reference value trouble (MAGENTA)
The low-density rising point or the high-density saturation point cannot be calculated because of a calculation error in the primary approximation formula of the sensor output ratio for the LSU PWM value obtained from the first step patch print result when executing the half tone process control in MAGENTA.
The low-density rising point or the high-density saturation point cannot be calculated because of a calculation error in the primary approximation formula of the sensor output ratio for the LSU PWM value obtained from the first step patch print result when executing the half tone process control in MAGENTA.
Causes: Image density sensor trouble, harness connection trouble between PCU sub PWB and the image density sensor, image density sensor dirt, transfer belt cleaning trouble
Remedy: Use SIM44-2 to execute the process control gain adjustment. If "ERROR" is displayed, check the sensor and the harness. If the adjustment is completed, check the drum surface state and the belt surface state.