Code: F2-93
Description: High-density process control density correction error (MAGENTA)
The patch density value is not in the range of the density correction reference density value (STD value) ±30% at the upper limit or the lower limit bias voltage when executing the high density process control.
The patch density value is not in the range of the density correction reference density value (STD value) ±30% at the upper limit or the lower limit bias voltage when executing the high density process control.
Causes: Image density sensor trouble, harness connection trouble between PCU PWB-image density sensor, dirt on image density sensor, transfer belt cleaning trouble
Remedy: 1) Use SIM44-2 to execute the process control sensor gain adjustment. 2) If an error occurs, check the sensors and the harnesses. 3) If the adjustment of 1) is completed, check the drum surface state, the belt surface state, etc.