Code: U2-90
Description: EEPROM read/write error (PCU detection)
EEPROM version error, write error to EEPROM
EEPROM version error, write error to EEPROM
Causes: EEPROM trouble, installation of EEPROM which is not initialized PCU PWB EEPROM access circuit trouble
Remedy: Case 1 Cause EEPROM trouble, installation of EEPROM which is not initialized Check and remedy Check that EEPROM is properly set. Case 2 Cause PCU PWB EEPROM access circuit trouble Check and remedy To avoid deletion of the counter data/adjustment data, use the simulation to save the counter/ adjustment values. (If there is a printer option, execute SIM22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use SIM16 to cancel the trouble.