Mã lỗi U6-51 — Sharp MX5140N
Code:
U6-51
Description: LCC - Main unit combination trouble
Causes: LCC control PWB trouble PCU PWB trouble
Remedy: Check to confirm the LCC model. Check the LCC control PWB, and replace if necessary. Check the PCU PWB, and replace if necessary.