Mã lỗi U6-09 — Sharp MX6201N
Code:
U6-09
Description: LCC lift motor trouble
Causes: Sensor trouble, LCC control PWB trouble, gear breakage, lift motor trouble
Remedy: Use SIM4-2 and 4-3 to check the operation of the sensor and the lift motor. Use SIM15 to cancel the trouble.