Code: U2-90
Description: EEPROM read/write error (PCU detection)
Causes: EEPROM version error, write error to EEPROM
Remedy: Case 1 Cause EEPROM trouble, installation of EEPROM which is not initialized. Installation of 64KBit EEPROM Check and remedy Check that EEPROM is properly set. Check to insure that 256KBit EEPROM is installed. Case 2 Cause PCU PWB EEPROM access circuit trouble Check and remedy To avoid deletion of the counter data/adjustment values, use the simulation to save the counter/ adjustment values. (If there is a printer option, execute SIM22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use SIM16 to cancel the trouble.