Code: E6-11
Description: Shading trouble (White correction) (DSPF)
Causes: CCD white scan level abnormality when the copy lamp is on.
Remedy: Case 1 Cause Installation error of the CCD unit flat cable Check and remedy Check the installing state of the flat cable to the CCD unit. Case 2 Cause Dirt on the mirror, the lens, or the reference white plate. Check and remedy Clean the mirror, the lens, or the reference white plate. Case 3 Cause Copy lamp lighting trouble Check and remedy Check the installing state of the flat cable to the copy lamp unit. Case 4 Cause CCD unit abnormality Check and remedy Check the CCD unit. Case 5 Cause DSPF PWB abnormality Check and remedy Check the DSPF PWB.