Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi H7-14 — Sharp MX7500N

Code: H7-14

Description: Low temperature detection during the temperature control reset operation after stopping the alarm in a JOB (HL_EX1)
Causes: When the alarm is stopped, the set temperature is not reached within the specified time. * Alarm stop: When the fusing temperature falls below the specified level in a print JOB, printing is interrupted temporarily and the temperature is reset.
Remedy: Case 1 Cause Connector and harness connection trouble Check and remedy Check connection of the connector and the harness. Case 2 Cause Thermistor trouble, thermostat trouble, heater lamp trouble, PCU PWB trouble, AC power source trouble, interlock switch trouble Check and remedy Use SIM 5-2 to check lighting of the heater lamp. Check conduction of the thermostat. Replace the heater lamp, the PCU PWB, and the AC PWB.

← Xem tất cả mã lỗi Sharp MX7500N