Code: E7 01
Description: Image data error. 1) The memory capacity for the duplex model machine is improper. Insufficient memory capacity 2) Duplex setting for the single-surface model.
Causes: 1) The memory capacity on the MCU PWB is improper. 2) Wrong setting for the single-surface model.
Remedy: 1) Use SIM26-39 to check to confirm that the memory capacity is 64MB. If it is not 64MB, replace the MCU PWB. 2) If SIM26-04 is set to 1, set it to 0. If the setting is 0, replace the MCU PWB.