Description: CL drum phase sensor trouble
Causes: Drum phase sensor trouble. (DHPCL) Harness and connector connection trouble. Drum drive section trouble. MFPC PWB trouble.
Remedy: Use SIM30-1 to check the operation of "DHPD_CL". Replace the drum phase sensor. Check connection of the connectors and the harness. Repair the drum drive section. Replace the MFPC PWB.