Code: F0-83
Description: Finisher paper guide motor section abnormality (FNM120)
Causes: Motor lock, control PWB trouble, disconnection of harness or connector, HP sensor breakdown.
Remedy: Use SIM3-3 to check the operation of the paper guide motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.