Mã lỗi L4-29 — Sharp MXM1100
Code:
L4-29
Description: HDD cooling fan motor trouble. The motor lock signal is detected during rotation of the HDD fan motor.
Causes: Fan motor trouble. Harness connection trouble between the controller PWB and the fan motor. Control circuit trouble.
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the controller PWB and the fan motor.