Mã lỗi U2-30 — Sharp MXM1205
Code:
Tất cả lỗi (322)
A0-01
A0-02
A0-04
A0-05
A0-10
A0-11
A0-14
A0-15
A0-16
A0-17
A0-20
A0-21
A0-22
C1-01
C1-10
C4-20
E6-10
E6-11
E6-14
E7-01
E7-02
E7-03
E7-03
E7-04
E7-07
E7-10
E7-11
E7-14
E7-20
E7-21
E7-24
E7-28
E7-29
E7-35
E7-36
E7-37
E7-42
E7-46
E7-48
E7-49
E7-50
E7-55
E7-58
E7-60
E7-61
E7-62
E7-65
E7-70
E7-71
E7-80
E7-89
E7-90
E7-91
E7-92
E7-93
E7-94
E7-95
E7-96
E7-A0
E7-A5
EE-EC
EE-EL
EE-EU
F0-03
F0-08
F0-10
F0-11
F0-14
F0-15
F0-18
F0-19
F0-20
F0-23
F0-25
F0-28
F0-29
F0-30
F0-31
F0-32
F0-33
F0-34
F0-37
F0-40
F0-41
F0-42
F0-43
F0-44
F0-45
F0-46
F0-47
F0-48
F0-49
F0-51
F0-52
F0-53
F0-54
F0-55
F0-56
F0-60
F0-61
F0-62
F0-63
F0-64
F0-65
F0-70
F0-71
F0-72
F0-73
F0-74
F0-75
F0-76
F0-77
F0-80
F0-81
F0-82
F0-83
F0-84
F0-86
F0-90
F0-91
F0-92
F0-93
F0-94
F0-95
F1-00
F1-01
F1-08
F1-09
F1-10
F1-11
F1-13
F1-15
F1-23
F1-31
F1-33
F1-34
F1-35
F1-44
F1-45
F1-46
F1-47
F1-48
F1-50
F1-60
F1-64
F1-65
F1-66
F1-67
F1-86
F1-89
F1-90
F1-96
F1-97
F1-98
F1-99
F2-22
F2-33
F2-39
F2-40
F2-47
F2-58
F2-59
F2-64
F2-70
F2-74
F2-78
F2-91
F3-12
F3-22
F3-32
F3-42
F6-00
F6-01
F6-04
F6-21
F6-30
F6-97
F6-98
F9-91
F9-92
FF-00
FF-10
H2-00
H2-02
H2-03
H3-00
H3-02
H4-00
H4-02
H4-30
H5-01
H7-10
H7-12
L1-00
L2-10
L3-00
L4-01
L4-02
L4-03
L4-04
L4-14
L4-17
L4-27
L4-28
L4-30
L4-31
L4-32
L4-34
L4-36
L4-38
L4-39
L4-40
L4-41
L4-43
L4-46
L4-47
L4-48
L4-49
L4-50
L4-51
L4-52
L4-53
L4-54
L4-55
L4-58
L6-10
L8-01
L8-02
L8-20
P1-00
P1-01
P1-02
PC--
U1-01
U2-00
U2-05
U2-11
U2-30
U2-40
U2-41
U2-42
U2-50
U2-60
U2-80
U2-81
U2-90
U2-91
U5-00
U5-16
U5-30
U5-31
U6-09
U6-20
U6-21
U6-22
U6-23
U6-24
U6-29
U6-33
U6-34
U6-39
U6-43
U6-44
U6-49
U6-51
U6-53
U6-54
U6-63
U6-68
U6-69
U6-73
U6-74
U6-79
U6-81
U6-82
U6-83
U6-84
U6-85
U6-86
U6-87
U6-88
U6-89
U6-90
U7-50
U7-51
U9-01
UC-02
UC-12
UC-20
UC-30
UE-10
UE-11
UE-12
UE-13
UE-14
UE-15
UE-16
UE-17
UE-20
UE-21
UE-22
UE-23
UE-24
UE-25
UE-26
UE-27
UE-30
UE-31
UE-32
UE-33
UE-34
UE-35
UE-36
UE-37
UE-40
UE-41
UE-42
UE-43
UE-44
UE-45
UE-46
UE-47
Code:
U2-30
Description: MFPC PWB and PCU PWB manufacturing No. data inconsistency
Causes: When replacing the PCU PWB or the MFPC PWB, the EEPROM which was mounted on the PWB before replacement is not mounted on the new PWB. MFPC PWB trouble PCU PWB trouble
Remedy: Check that the EEPROM is properly set. Check to confirm that the EEPROM which was mounted on the PWB before replacement is mounted on the new PWB. Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the MFPC PWB in the Service Manual, and perform the works.) Replace the PCU PWB.