Description: Paper feed tray 3 lift operation trouble
Causes: C3LUD does not turn ON within the specified time. C3LUD sensor trouble. Paper feed tray 3 lift unit trouble. PCU PWB trouble. Sensor harness and connector connection trouble
Remedy: Check the harness and the connector of C3LUD. Replace the lift-up unit. Replace the PCU PWB.