Code: F2-39
Description: Process thermistor breakdown
When the input value of the process thermistor is detected as 235 or greater or 22 or smaller for 3 times continuously.
When the input value of the process thermistor is detected as 235 or greater or 22 or smaller for 3 times continuously.
Causes: Improper connection of the process thermistor harness.
Process thermistor trouble
PCU PWB trouble
Process thermistor trouble
PCU PWB trouble
Remedy: Case 1 Cause Improper connection of the process thermistor harness. Check and remedy Check connection of the connector and the harness of the process thermistor. Case 2 Cause Process thermistor trouble Check and remedy Check the process thermistor. Case 3 Cause PCU PWB trouble Check and remedy Check the PCU PWB.