Code: F1-32
Description: Finisher-saddle communication trouble
Communication error between the finisher and the saddle When the motor rotation speed (linear velocity) at every 200msec falls below the specified level. When moving to the home position, the home position sensor does not turn on within the specified time. When shifting from the home position to the lead edge, the home position sensor does not turn off within the specified time.
Communication error between the finisher and the saddle When the motor rotation speed (linear velocity) at every 200msec falls below the specified level. When moving to the home position, the home position sensor does not turn on within the specified time. When shifting from the home position to the lead edge, the home position sensor does not turn off within the specified time.
Causes: Improper connection or disconnection of the connector and the harness between the finisher and the saddle unit.
Finisher control PWB trouble Control PWB (PCU) trouble
Malfunction caused by noises
Finisher control PWB trouble Control PWB (PCU) trouble
Malfunction caused by noises
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the finisher and the saddle unit. Check and remedy Check the connector and the harness in the communication line. Case 2 Cause Finisher control PWB trouble Control PWB (PCU) trouble Check and remedy Replace the finisher control PWB. Case 3 Cause Malfunction caused by noises Check and remedy Canceled by turning ON/ OFF the power.