Code: E6-14
Description: CIS communication trouble
When an error occurs in an access check to the CIS-ASIC on turning on the power or closing the DSFP cover. (Retry number: 5 times) Communication trouble between the scanner PWB and the CIS-ASIC. (Clock synchronization)
When an error occurs in an access check to the CIS-ASIC on turning on the power or closing the DSFP cover. (Retry number: 5 times) Communication trouble between the scanner PWB and the CIS-ASIC. (Clock synchronization)
Causes: Defective installation of the harness to the CIS unit
CIS unit abnormality
Scanner PWB check
CIS unit abnormality
Scanner PWB check
Remedy: Case 1 Cause Defective installation of the harness to the CIS unit Check and remedy Check the harness connected to the CIS unit. Case 2 Cause CIS unit abnormality Check and remedy CIS unit check Case 3 Cause Scanner PWB abnormality Check and remedy Scanner PWB check