Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi F2-32 — Sharp MXM550U

Code: F2-32

Description: Process control trouble (Drum marking scan trouble)
The drum marking size, density, or the number of units is improper.
Causes: Drum marking sensor trouble
Improper connection of the harness between the PCU PWB and the drum marking sensor
The drum marking sensor is dirty. OPC drum cleaning trouble
Remedy: Case 1 Cause Drum marking sensor trouble Check and remedy Use SIM 44-02 to perform the process control sensor gain adjustment. Case 2 Cause Improper connection of the harness between the PCU PWB and the drum marking sensor Check and remedy If "Error" is displayed, it may be considered as a breakdown. Check the sensor and the harness. Case 3 Cause The drum marking sensor is dirty. OPC drum cleaning trouble Check and remedy If the adjustment is completed, check the drum surface conditions.