Code: U2-12
Description: Adjustment value check sum error (MFP control)
EEPROM counter area checksum error (If this error occurs, the process will retrieve for effective data within 8 blocks.)
EEPROM counter area checksum error (If this error occurs, the process will retrieve for effective data within 8 blocks.)
Causes: EEPROM trouble
Control circuit runaway due to noises
MFP control PWB EEPROM access circuit trouble
Control circuit runaway due to noises
MFP control PWB EEPROM access circuit trouble
Remedy: Case 1 Cause EEPROM trouble Check and remedy Check that the EEPROM is properly installed. In the simulation to prevent against delete of the counter data/adjustment values, write down the counter/adjustment values. Case 2 Cause Control circuit runaway due to noises Check and remedy Use SIM 16 to cancel the U2 trouble. Case 3 Cause MFP control PWB EEPROM access circuit trouble Check and remedy Replace the MFP control PWB.