Mã lỗi U2-50 — Sharp MXM550U

Code: U2-50

Description: HDD section individual data check sum error (MFP control)
Check sum error for every individual data in HDD of the MFPC section when turning on the power
(If this error occurs, initialize the data related to the check sum error. (One-touch, group, program, etc.))
Causes: HDD write/read error
Control circuit runaway due to noises
MFP control PWB HDD access circuit trouble
Remedy: Case 1 Cause HDD write/read error Check and remedy Automatically initialize the data related to the check sum error by turning OFF/ON the power. Since the registered data are deleted, register the data again. Case 2 Cause Control circuit runaway due to noises Check and remedy Use SIM 16 to cancel the U2 trouble. Case 3 Cause MFP control PWB HDD access circuit trouble Check and remedy Replace the HDD. Replace the MFP control PWB.