Code: C1-00
Description: MC trouble
Three successive MHV-T signals are detected during operation of MHV. Main charger output abnormality (Output open) A trouble signal is outputted from the high voltage transformer.
Three successive MHV-T signals are detected during operation of MHV. Main charger output abnormality (Output open) A trouble signal is outputted from the high voltage transformer.
Causes: The main charger is not installed properly. The main charger is not assembled properly.
The high voltage transformer connector is disconnected. The high voltage harness is disconnected or broken.
High voltage unit trouble
The high voltage transformer connector is disconnected. The high voltage harness is disconnected or broken.
High voltage unit trouble
Remedy: Case 1 Cause The main charger is not installed properly. The main charger is not assembled properly. Check and remedy Use SIM 8-2 to check the main charger output. Main charger disconnection check Case 2 Cause The high voltage transformer connector is disconnected. The high voltage harness is disconnected or broken. Check and remedy Connection check Case 3 Cause High voltage unit trouble Check and remedy Replace the high voltage unit.