Code: L4-31
Description: Paper discharging fan trouble
When the detected value of the temperature sensor (TH_EX) in the paper exit reverse unit is greater than the specified level for 2 times continuously in the interval of 30sec. When 100°C (value of 235) of the paper exit thermistor is detected for 3 times continuously. (In the interval of 100ms)
When the detected value of the temperature sensor (TH_EX) in the paper exit reverse unit is greater than the specified level for 2 times continuously in the interval of 30sec. When 100°C (value of 235) of the paper exit thermistor is detected for 3 times continuously. (In the interval of 100ms)
Causes: Fan motor trouble
PCU PWB, harness connection between fan and motor trouble PCU circuit trouble
Thermistor (TH_EX) trouble
PCU PWB, harness connection between fan and motor trouble PCU circuit trouble
Thermistor (TH_EX) trouble
Remedy: Case 1 Cause Fan motor trouble Check and remedy Use SIM 6-2 to check the fan motor operation. Case 2 Cause PCU PWB, harness connection between fan and motor trouble PCU circuit trouble Thermistor (TH_EX) trouble Check and remedy Check the PCU PWB, the harness between fan and motor, and the connector.