Code: E7-01
Description: System data trouble
While reading/writing the HDD system area data, the HDD returns an error response or no response at all for longer than 30 seconds.
While reading/writing the HDD system area data, the HDD returns an error response or no response at all for longer than 30 seconds.
Causes: No HDD is installed on the MFP control
PWB.HDD does not properly function.
MFP control PWB abnormality
PWB.HDD does not properly function.
MFP control PWB abnormality
Remedy: Case 1 Cause No HDD is installed on the MFP control PWB. Check and remedy Check installation status of the HDD on the MFP control PWB. Case 2 Cause HDD does not properly function. Check and remedy • CHECK connection between the HDD and MFP control. • Perform an HDD read/write test using SIM 62-2/3. • Replace HDD. Case 3 Cause MFP control PWB abnormality Check and remedy Replace the MFP control PWB.