Code: EE-EL
Description: Auto developer adjustment trouble (Overtoner error)
Described on the toner density control design sppecifications and the change request. When the average of 10 output values of the toner sensor (sampling data) after completion (3 min) of the auto development adjustment is smaller than 1.5V.
Described on the toner density control design sppecifications and the change request. When the average of 10 output values of the toner sensor (sampling data) after completion (3 min) of the auto development adjustment is smaller than 1.5V.
Causes: Toner density sensor trouble. Charging voltage and developing voltage trouble. Toner density trouble Developing unit trouble PCU PWB trouble.
Remedy: Use SIM 25-2 to perform the automatic developing adjustment.