Code: U6-09
Description: LCC lift motor trouble
• The upper limit sensor is not turned on within 24sec from starting the liftup motor. • The encoder input is not made within 0.2sec during rotation of the liftup motor. The upper limit SW is turned on during rotation of the liftup motor. When the above trouble occurs for 3 times continuously. • For the first time and the second time, it is a tray size error and the user pulls the tray. When the trouble occurs 3 time continuously that the upper limit sensor does not turn on.
• The upper limit sensor is not turned on within 24sec from starting the liftup motor. • The encoder input is not made within 0.2sec during rotation of the liftup motor. The upper limit SW is turned on during rotation of the liftup motor. When the above trouble occurs for 3 times continuously. • For the first time and the second time, it is a tray size error and the user pulls the tray. When the trouble occurs 3 time continuously that the upper limit sensor does not turn on.
Causes: Sensor trouble LCC control PWB trouble. Gear breakage. Lift motor trouble.
Remedy: Use SIM to check the sensor detection. Use SIM to check the lift motor operation. Use SIM 15 to cancel the trouble.