Code: F2-37
Description: Drum marking sensor gain adjustment error
Before starting process control, the drum marking area surface is read by the sensor to make the sensor gain adjustment so that the output is fixed to a certain level. Though the sensor gain is changed, the output is not fixed to a certain level.
Before starting process control, the drum marking area surface is read by the sensor to make the sensor gain adjustment so that the output is fixed to a certain level. Though the sensor gain is changed, the output is not fixed to a certain level.
Causes: Drum marking sensor trouble
Improper connection of the harness between the PCU PWB and the drum marking sensor
The drum marking sensor is dirty. OPC drum cleaning trouble
Improper connection of the harness between the PCU PWB and the drum marking sensor
The drum marking sensor is dirty. OPC drum cleaning trouble
Remedy: Case 1 Cause Drum marking sensor trouble Check and remedy Use SIM 44-02 to perform the process control sensor gain adjustment. Case 2 Cause Improper connection of the harness between the PCU PWB and the drum marking sensor Check and remedy If "Error" is displayed, it may be considered as a breakdown. Check the sensor and the harness. Case 3 Cause The drum marking sensor is dirty. OPC drum cleaning trouble Check and remedy If the adjustment is completed, check the drum surface conditions.