Code: H3-01
Description: Fusing section high temperature trouble (HL2)
The fusing temperature exceeds 241.5 °C. (An input voltage of 1.3V or less is detected.) When fusing temperature control is started and a temperature of 242 °C is detected 3 times continuously in sampling of 250 msec interval. (In the interval of 150ms)
The fusing temperature exceeds 241.5 °C. (An input voltage of 1.3V or less is detected.) When fusing temperature control is started and a temperature of 242 °C is detected 3 times continuously in sampling of 250 msec interval. (In the interval of 150ms)
Causes: Thermistor trouble. Control PWB trouble.
Improper connection of the fusing section
connector. AC power trouble.
Improper connection of the fusing section
connector. AC power trouble.
Remedy: Use SIM 5-2 to check flashing of the heater lamp. When the lamp flashes normally. • Check the thermistor and the harness. • Check the thermistor input circuit on the control PWB. When the lamp keeps ON. • Check the AC PWB and the lamp control circuit on the control PWB. Use SIM 14 to cancel the trouble