Code: H4-01
Description: Fusing section low temperature trouble (HL2)
The set temperature is not reached within the specified time (normally 3 min or 5 min in the curl prevention mode) after turning on the power relay. When the heater lamp is not turned off in 4 min after starting the warm-up operation. When the set value of -40°C is detected for 5 times continuously in the specified interval after completion of the warm-up operation. (In the interval of 150ms)
The set temperature is not reached within the specified time (normally 3 min or 5 min in the curl prevention mode) after turning on the power relay. When the heater lamp is not turned off in 4 min after starting the warm-up operation. When the set value of -40°C is detected for 5 times continuously in the specified interval after completion of the warm-up operation. (In the interval of 150ms)
Causes: Thermistor trouble Heater lamp trouble
Control PWB trouble Thermostat trouble
AC power trouble Interlock switch
Control PWB trouble Thermostat trouble
AC power trouble Interlock switch
Remedy: Use SIM 5-2 to check flashing of the heater lamp. When the lamp flashes normally. • Check the thermistor and the harness. • Check the thermistor input circuit on the control PWB. When the lamp does not turn on. • Check for disconnection of the heater lamp or the thermostat. • Check the interlock switch. • Check the AC PWB and the lamp control circuit on the control PWB. Use SIM 14 to cancel the trouble