Code: E7-12
Description: CCD shading trouble (White correction center adjustment)
The CCD white reference plate scan level abnormality when lighting the copy lamp
When the proper gain setup value is not obtained at turning on the power or CCD shading with SIM 63-2. (Retry number 256 times)
The CCD white reference plate scan level abnormality when lighting the copy lamp
When the proper gain setup value is not obtained at turning on the power or CCD shading with SIM 63-2. (Retry number 256 times)
Causes: Mirror, lens, reference white plate dirt
Copy lamp lighting abnormality
Defective installation of the flat cable to the CCD unit. Improper installation of the CCD unit 3 CCD unit abnormality.
Scanner PWB abnormality
Copy lamp lighting abnormality
Defective installation of the flat cable to the CCD unit. Improper installation of the CCD unit 3 CCD unit abnormality.
Scanner PWB abnormality
Remedy: Case 1 Cause Mirror, lens, reference white plate dirt Check and remedy Clean the mirror, the lens, and the reference white plate Case 2 Cause Copy lamp lighting abnormality Check and remedy Check the light quantity and lighting of the copy lamp. (SIM 5-3) Case 3 Cause Defective installation of the flat cable to the CCD unit. Improper installation of the CCD unit 3 CCD unit abnormality. Check and remedy CCD unit check Case 4 Cause Scanner PWB abnormality Check and remedy Scanner PWB check