Code: F1-60
Description: Finisher-inserter communication trouble
Finisher/inserter communication trouble
Finisher/inserter communication trouble
Causes: Improper connection or disconnection of the connector and the harness between the finisher and the inserter unit
Finisher control PWB trouble. Control PWB (PCU) trouble.
Malfunction caused by noises
Finisher control PWB trouble. Control PWB (PCU) trouble.
Malfunction caused by noises
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the finisher and the inserter unit Check and remedy Check the connector and the harness in the communication line. Case 2 Cause Finisher control PWB trouble. Control PWB (PCU) trouble. Check and remedy Replace the finisher control PWB. Case 3 Cause Malfunction caused by noises Check and remedy Canceled by turning ON/ OFF the power.