Code: U2-81
Description: Memory check sum error (Scanner)
When counter data sum error is detected.
When counter data sum error is detected.
Causes: EEPROM trouble
Control circuit runaway due to noises
Scanner PWB EEPROM access circuit trouble
Control circuit runaway due to noises
Scanner PWB EEPROM access circuit trouble
Remedy: Case 1 Cause EEPROM trouble Check and remedy Check that the EEPROM is properly installed. In the simulation to prevent against delete of the counter data/adjustment values, write down the counter/adjustment values. Case 2 Cause Control circuit runaway due to noises Check and remedy Use SIM 16 to cancel the U2 trouble. Case 3 Cause Scanner PWB EEPROM access circuit trouble Check and remedy Replace the scanner PWB.