Code: F2-02
Description: Toner supply abnormality
Toner remains in the toner bottle when undertoner is detected by the toner concentration sensor in the developing unit.
Toner remains in the toner bottle when undertoner is detected by the toner concentration sensor in the developing unit.
Causes: Toner concentration sensor trouble. Toner remaining quantity sensor trouble. Connector harness trouble for the above sensors.
Remedy: Check connector of hopper unit toner motor (TM1) Check connector of toner bottle toner motor (TM2) Check connection of the connector harnesses to the main PWB. Check broken harness for above connections. Check output of the toner concentration sensor (SIM25-1). Check output of the toner remaining quantity sensor (SIM10-2).