Code: L4-06
Description: Transfer belt separation motor trouble detection
Transfer belt separation motor trouble detection The transfer belt home position sensor ON/OFF is not detected within the specified time (4 sec) during operation of the transfer belt (separation, contact).
Transfer belt separation motor trouble detection The transfer belt home position sensor ON/OFF is not detected within the specified time (4 sec) during operation of the transfer belt (separation, contact).
Causes: Transfer belt separation motor trouble
Improper connection of the harness between the PCU PWB and the transfer belt separation motor. Control circuit trouble
Improper connection of the harness between the PCU PWB and the transfer belt separation motor. Control circuit trouble
Remedy: Case 1 Cause Transfer belt separation motor trouble Check and remedy Use SIM 6-1 to check the transfer belt motor operation. Case 2 Cause Improper connection of the harness between the PCU PWB and the transfer belt separation motor. Control circuit trouble Check and remedy Check connection of the harness and the connection of the harness between the PCU PWB and the transfer belt separation motor.