Code: U2-91
Description: Memory check sum error (PCU)
When POF data/counter data sum error is detected.
When POF data/counter data sum error is detected.
Causes: EEPROM trouble
Control circuit runaway due to noises
PCU PWB EEPROM access circuit trouble
Control circuit runaway due to noises
PCU PWB EEPROM access circuit trouble
Remedy: Case 1 Cause EEPROM trouble Check and remedy Check that the EEPROM is properly installed. In the simulation to prevent against delete of the counter data/adjustment values, write down the counter/adjustment values. Case 2 Cause Control circuit runaway due to noises Check and remedy Use SIM 16 to cancel the U2 trouble. Case 3 Cause PCU PWB EEPROM access circuit trouble Check and remedy Replace the PCU PWB.