Mã lỗi F1-62 — Sharp MXM753U
Code:
F1-62
Description: Inserter reverse sensor trouble
Causes: Sensor breakage. Harness disconnection. Inserter PWB trouble.
Remedy: Use SIM3-2 to check the operation of the sensor. Replace the inserter control PWB.