Code: U6-43
Description: LCT3 lift-down trouble. The lower limit position (full state) of the LCT3 tray is not detected within the specified time (A4: 10sec, A3: 8sec) from starting lowering
Causes: Remaining quantity sensor abnormality, LCT3 tray liftup motor lock, connector / harness connection trouble, PWB trouble.
Remedy: Use Sim. 4-2 and Sim. 4-3 to check the operation of the remaining quantity sensor and the LCT3 tray lift-up motor, and check the wiring.