Code: F0-34
Description: Finisher punch motor section abnormality (FNM117)
The punching operation of the punch unit in the finisher is abnormal.
The punching operation of the punch unit in the finisher is abnormal.
Causes: Motor lock, control PWB trouble, disconnection of harness or connector, HP sensor breakdown.
Remedy: Use SIM3-3 to check the operation of the punch motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.