Code: F1-86
Description: Return drive motor trouble (finisher + saddle unit + inserter) Return collar oscillation motor trouble (saddle finisher). Return drive motor abnormality in the finisher compiler
Causes: Motor lock, motor harness short/open, control PWB trouble, home position sensor trouble, connection harness / connector connection trouble.
Remedy: Use Sim. 3-3 to check the operation of the return drive motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.