Mã lỗi F3-12 — Sharp MXM950
Code:
F3-12
Description: Machine cassette 1 lift-up trouble. LUD1 is not turned ON within the specified time.
Causes: LUD1 sensor trouble. Cassette 1 lift-up motor trouble. Harness connection trouble of PCU PWB, the lift-up unit, and the paper feed unit.
Remedy: Check connection of the harness and the connector of LUD1. Check the lift-up unit.
← Xem tất cả mã lỗi Sharp MXM950