Code: U6-33
Description: LCT2 lift-down trouble. The lower limit position (full state) of the LCT2 tray is not detected within the specified time (A4: 10sec, A3: 8sec) from starting lowering.
Causes: Remaining quantity sensor abnormality, LCT2 tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy: Use Sim. 4-2 and Sim. 4-3 to check the operation of the remaining quantity sensor and the LCT2 tray lift-up motor, and check the wiring.