Description: Print head abnormal VSH voltage error (support number : 4801)
Causes: Abnormal VSH voltage of the print head is detected.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to check the result of LONG FFC CHECK and if CRC value changes after turning the printer off and back on (When CRC value changes, wires are broken). Without broken wires Go to 2. With broken wires Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)