Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi EC22 2F47 — Canon iPF PRO 2000

Code: EC22 2F47

Description: Abnormal HEAD MANAGEMENT SENSOR UNIT error (support number : 4801)
Causes: Abnormal HEAD MANAGEMENT SENSOR UNIT is detected at starting up and non- ejection detection.
Remedy: 1 Check the items below. a) Adherence of paper dust and hairs on the HEAD MANAGEMENT SENSOR UNIT. b) Adherence or laying-up of large amount of ink mist on the HEAD MANAGEMENT SENSOR UNIT. c) Connector condition. Appropriate condition and proper connection Go to 2. Inappropriate condition or improper connection a) Remove it. b) Perform cleaning or replace HEAD MANAGEMENT SENSOR UNIT. c) Connect the connector. 2 Check if the fuse (FU5202) on MAIN PCB UNIT is disconnected. Connected Replace HEAD MANAGEMENT SENSOR UNIT. Disconnected Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)