Code: 10-100
Description: Fuser Temperature (Open) Fault The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ± 5°C.)
Remedy: Power Off the machine and check that the Fuser connection is fully seated . The Fuser connections are OK. Firmly reconnect the Fuser assembly. Switch the power ON. Check for +3.3 VDC to the Thermistor at P/J on Main PWB. The voltage is OK. • Check the wire harness for open or short circuits. • Replace the Main PWB , Check the voltage to the Over Heat Thermostat. The voltage is OK. • Check for AC line voltage to the LVPS PWB . • Check the wire harness for open or short circuits. • Replace the LVPS PWB if needed. Check the Heat Lamp for an open circuit. Repair or replace the Fuser Assembly as required.