Code: EC31 2F1C
Description: Purge main cam sensor error (support number : 4801)
Causes: The following failure is detected. • Initialization of purge main cam position is failed. • CARRIAGE UNIT is not able to be moved to the specified position when capping.
Remedy: 1 Check the items below. a) The foreign substances such as paper debris are adhering around PURGE UNIT. b) Scratch or stain on FILM, TIMING SLIT STRIP. Without paper debris, scratch, and stain Go to 2. With paper debris, scratch, and stain a) Remove the foreign substance. b) Perform cleaning or replace FILM, TIMING SLIT STRIP. 2 After unlocking CARRIAGE UNIT with [FUNCTION > CR UNLOCK], perform [FUNCTION > CR LOCK] to check CARRIAGE UNIT lock operation. Proper operation Reboot and recheck the operation. Abnormal operation Replace PURGE UNIT.