Code: 08-700
Description: Output Tray Full Fault The Output Tray Full Sensor has detected that the Output Tray is full.
Remedy: Enter Diagnostic (EDC) Mode. Select: [DC330 Component Control, 102-Sensor, Out Bin Full] to test the Out Bin Full Sensor. The signal changes. • Check that the sensor connector is firmly seated. • Replace the Out Bin Full Sensor. Check actuator for binding. If the problem is intermittent, replace the Out Bin Full Sensor Actuator.