Description: 050-131 IOT Remain Zone Duplex Jam 077-107 Duplex Regi On Jam 050-131 is displayed in the UI. 077-107 is registered in the Error Log. Cause: 050-131: When Dynamic Jam (cause) was detected: - 077-107 Duplex Regi On Jam 077-107: After the Invert Clutch turned ON, the Regi. Sensor did not turn ON within the specified time.
Remedy: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-102] to check the operation of the Regi. Sensor HVPS. • Is the Regi. Sensor HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071- 008] to check the operation of the CLUTCH ASSEMBLY INVERT. • Is the CLUTCH ASSEMBLY INVERT operating normally? Step 6 Go to FIP 2.09 6 • Execute the Diag Digital Output [071- 001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15