Description: 091-914 IOT Drum Communication Fail 091-915 Drum CRUM Data Broken Fail 091-921 IOT Drum Detached 091-963 IOT Drum CRUM ID Error Cause: 091-914: Communication failure with Drum CRUM was detected. 091-915: Malfunction of Drum CRUM was detected. 091-921: It was detected that the Drum CRUM is not at the specified position.(Loose CRUM) 091-963: The Drum CRUM ID error was detected.
Remedy: 1 Is the DRUM CARTRIDGE installed properly, with no foreign substances at the contact point between the CRUM in the DRUM CARTRIDGE and the XEROGRAPHIC CONNECTOR ASSEMBLY? Go to Step 2. Reinstall the DRUM CARTRIDGE 2 Is the DRUM CARTRIDGE, which is installed in the device, a genuine product? Go to Step 3. Replace the DRUM CARTRIDGE with a genuine product 3 Is the connection terminal of the CRUM part in the DRUM CARTRIDGE damaged? Replace the DRUM CARTRIDGE Go to Step 4. 4 Is the connection terminal of the XEROGRAPHIC CONNECTOR ASSEMBLY damaged? Replace (Xerographic Connector Assembly) Go to Step 5. 5 • Check the connection between the XEROGRAPHIC CONNECTOR ASSEMBLY and the MCU PWB. • Is the XEROGRAPHIC CRUM HARNESS ASSEMBLY (P/J254 - P/J25) connected securely? Go to Step 6. Securely connect the XEROGRAPHIC CRUM HARNESS ASSEMBLY 6 • Replace the DRUM CARTRIDGE. • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace (Xerographic Connector Assembly) • Does an error occur? Go to Step 8. Troubleshooting complete. 8 • Replace the XEROGRAPHIC CRUM HARNESS ASSEMBLY. • Does an error occur? Replace (MCU PWB) Troubleshooting complete.