Code: 04-400-00
Description: Tray 5 Lift Error
Causes: Tray 5 Level Sensor did not change state within 13 seconds of Lift Motor activation.
Remedy: • Remove and replace Tray 5. • Check for obstructions blocking bottom plate movement. • Reorder Feeder position to isolate the problem.
Cycle system power. The error message is displayed. Y↓ N→Complete. Check Tray 5 bottom plate linkage and sector gear condition. Use an alternate Tray to test lift operation.The Tray is undamaged. Y↓ N→Replace the Tray. Check the Pick Assembly (PL 8.20) motion. Pick assembly motion is good. Y↓ N→Repair improper Pick Assembly motion. Select dC330 code 07-550. The sensor is operational (high/low). Y↓ N→Repair or replace the Level Sensor. Check the Lift Gear, PL 8.35 Item 4. The gear is undamaged and properly installed. Y↓ N→Replace the Lift Gear. Remove the IOT, Tray 3 and Tray 4 from the Feeder. Reassemble the system to exchange Feeder positions. The error message changes to the new feeder position. Y↓ N→Check the IOT Lower Option Harness. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace the MCU Board. Test Lift Motor operation in the affected Feeder. The Lift Motor rotates. Y↓ N→Remove the Right Cover , reseat CN2 on the Feeder Board, then retest. The Lift Motor rotates. Y↓ N→Check the Feeder Upper Option Harness. The harness is undamaged. Y↓ N→Repair or replace the harness. Replace the Lift Motor, then retest. The Lift Motor rotates. Y↓ N→Replace the Feeder Board. Reassemble and perform SCP 6 Final Actions. Reassemble and perform SCP 6 Final Actions. Replace these components in order until the error is corrected. 1. Tray, PL 7.10 Item 23 2. Feeder Board, PL 8.30 Item 7 3. MCU Board, PL 3.10 Item 3
Cycle system power. The error message is displayed. Y↓ N→Complete. Check Tray 5 bottom plate linkage and sector gear condition. Use an alternate Tray to test lift operation.The Tray is undamaged. Y↓ N→Replace the Tray. Check the Pick Assembly (PL 8.20) motion. Pick assembly motion is good. Y↓ N→Repair improper Pick Assembly motion. Select dC330 code 07-550. The sensor is operational (high/low). Y↓ N→Repair or replace the Level Sensor. Check the Lift Gear, PL 8.35 Item 4. The gear is undamaged and properly installed. Y↓ N→Replace the Lift Gear. Remove the IOT, Tray 3 and Tray 4 from the Feeder. Reassemble the system to exchange Feeder positions. The error message changes to the new feeder position. Y↓ N→Check the IOT Lower Option Harness. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace the MCU Board. Test Lift Motor operation in the affected Feeder. The Lift Motor rotates. Y↓ N→Remove the Right Cover , reseat CN2 on the Feeder Board, then retest. The Lift Motor rotates. Y↓ N→Check the Feeder Upper Option Harness. The harness is undamaged. Y↓ N→Repair or replace the harness. Replace the Lift Motor, then retest. The Lift Motor rotates. Y↓ N→Replace the Feeder Board. Reassemble and perform SCP 6 Final Actions. Reassemble and perform SCP 6 Final Actions. Replace these components in order until the error is corrected. 1. Tray, PL 7.10 Item 23 2. Feeder Board, PL 8.30 Item 7 3. MCU Board, PL 3.10 Item 3